4 SYSTEM LOGIC
4.1 Power Subsystem
4.1.1 Power Rails
The Trim-Slice is powered with a single 12V power supply.
Table 7 Power signals
Main power supply. Typical voltage – 12V.
4.1.2 Power Modes
The Trim-Slice supports two hardware power modes.
Table 8 Power modes
All internal power rails are enabled. Mode entered automatically when main
power supply is connected.
All internal power rails except those required for the power management logic
are switched off.
4.1.3 RTC Back-Up Battery
The Trim-Slice features an on-board 18mAh rechargeable coin cell lithium battery, which maintains
the Trim-Slice RTC whenever the main power supply is not present.
4.2 Firmware Boot Options
The Trim-Slice supports the following firmware boot options:
Boot from on-board SPI NOR flash
Boot from external SD card inserted into the P2 SD socket
The boot option is selected with the recovery-boot button SW2. The default boot option is designed
for normal system operation with the on-board SPI NOR flash acting as the boot media. The alternate
boot option is intended mainly for system recovery.
NOTE: The recovery-boot button only affects the firmware (Tegra2 BCT and boot-loader) boot
process. O/S and file-system boot configuration is determined by the boot-loader
settings.
Table 9 Boot options
Recovery-boot button (SW2) state
Pressed during system reset / power cycle.